Note:
Order accessories (Hole Plugs
for unused spaces, QMA adaptors for RJ11 or RJ45 data/tel jacks,
etc.) separately.
| Order Reference Guide |
Page 1 |
Use this Guide as a work sheet for different
models
FMCA
Series Floor Box See FMCA Series
data sheets for detailed specifications
Step 1)
Determine how many and what kind of connectors you need. Then choose the Insert
Type(s)
from the
Moduline Insert Data Sheet or use Table 1 as a
reference.
Step 2) Choose which Series you need based on the required number of Inserts.
Note:
See HandHold Option Data Sheet for additonal options for 2000 and 3000 series.
1000
series - one Insert
2000 series - two Inserts
3000 series - four Inserts
Step 3)
Place the Door style number in the appropriate Series example below.
0 -
Steel, Black, Self Trimming - for carpet or hard surfaces
1 - Brass, Self Trimming - for carpet or hard surfaces
2 - Steel, Black, Flat - flush route-in for non-carpet surfaces
3 - Brass, Flat - flush route-in for non-carpet surfaces
4 - Steel, Black, Self Trimming, w/ Cable Door - for carpet or hard surfaces
8 - Stainless Steel, Self Trimming, w/ Cable Door - for carpet or hard surfaces
Step 4)
Place Insert Type number(s) in the appropriate Series example below.
FMCA 1 _
0 _ Order BB1000
backbox separately
Door style
Insert choice
FMCA 2 _
_ _ Order BB2000
backbox separately
Door style
Insert choices
FMCA 3 _
_ _ - _ _ Order BB3000
backbox separately
Door style
Insert choices
Table 1 - see the Moduline
Insert Data Sheet for complete details of Insert Types
Standard Inserts
included
in base cost
Type 1
 |
Type 2
 |
Type 3
 |
Type 4
 |
Type 8
 |
Type 9
 |
Type K
 |
|
|
Plus Inserts
additional
cost
Type Q
 |
Type V
 |
|
|
Custom Inserts
call for
details
Type C - Laser Cut
 |
|
R Option
additional
cost
Type R
 |
|
Need help?
If you have
a special application or just need a little technical assistance. Call toll free 800 798
2256 |

|
| Order Reference Guide |
Page 2 |
Use this Guide as a work sheet for different
models
LE Series
Enclosures See the LE Series
data sheets for detailed specifications
Step 1)
Choose the Insert Type(s) from the
Moduline Insert Data
Sheet or use Table 2
as a reference.
Note:for 2 gang opening in place of the inserts, order LE20GG.
Step 2) Place Insert Type number(s) in the example below to build a model number.
|
LE 1 0 0 _
Insert choice |
LE 2 0 _ _
Insert choice |
Note:
Order BBLE1 backbox , BBLE2 backbox and accessories (Hole Plugs for unused spaces, QMA
adaptors for RJ11 or RJ45 data/tel jacks, etc.) separately.
AW Series
Enclosure See AW Series data sheet
for detailed specifications
Step 1)
Choose the Insert Type(s) from the
Moduline Insert Data
Sheet or use Table 2 as a reference.
Step 2) Place Insert Type number(s) in the example below to build a model number.
|
For AW1000 Weather Resistant Series
AW 1 0 0 _
Insert
choice |
For AW2000 Weather Proof Series
AW 2 0 _ _
Insert choices |
Note:
Order accessories (Hole Plugs for unused spaces, QMA
adaptors for RJ11 or RJ45 data/tel jacks, etc.) separately.
Table 2 - see the Moduline
Insert Data Sheet for complete details of Insert Types
Standard Inserts
included in base
cost
Type 1
 |
Type 2
 |
Type 3
 |
Type 4
 |
Type 8
 |
Type 9
 |
Type K
 |
|
|
Plus Inserts
additional cost
Type Q
 |
Type V
 |
|
Custom Inserts
call for details
Type
C - Laser Cut
 |
|
Need help?
If you have a special
application or just need a little technical assistance. Call toll free 800 798 2256 |

|